Synced
DiagnosticHub.sinkFailed
Section titled “DiagnosticHub.sinkFailed”
- Occurs when a diagnostic presentation sink fails and is quarantined.
Required contracts
Section titled “Required contracts”API: engine
Project: Inno.Core.Diagnostics
Declaration
Section titled “Declaration”public System.Action<System.Exception>? Inno.Core.Diagnostics.DiagnosticHub.sinkFailedRemarks
Section titled “Remarks”Observers execute synchronously during publication. Without an observer, or when an observer throws, the current implementation reports to standard error; a failure of that secondary writer can propagate. Unregistration or quarantine does not dispose the presentation sink.